(redirected from audiophile)
Also found in: Dictionary, Thesaurus, Encyclopedia, Wikipedia.


the production of diagnostic images, e.g., radiography, ultrasonography, or scintigraphy.
digital subtraction imaging a technique in radiography in which electronic subtraction allows the visualization of individual images; see also digital subtraction angiography.
electrostatic imaging a method of visualizing deep structures of the body, in which an electron beam is passed through the patient and the emerging beam strikes an electrostatically charged plate, dissipating the charge according to the strength of the beam. A film is then made from the plate.
gated cardiac blood pool imaging equilibrium radionuclide angiocardiography.
horizontal beam imaging a grid positioning technique in radiology in which the grid cassette is positioned with its lead lines perpendicular to the floor.
hot spot imaging (infarct avid imaging) infarct avid scintigraphy.
magnetic resonance imaging see magnetic resonance imaging.
myocardial perfusion imaging myocardial perfusion scintigraphy.


Production of a clinical image using x-rays, ultrasound, CT, MRI, radionuclide scanning, and thermography; especially, cross-sectional imaging, such as ultrasonography. See: image.


/imag·ing/ (im´ah-jing) the production of diagnostic images, e.g., radiography, ultrasonography, or scintillation photography.
color flow Doppler imaging  a method of visualizing direction and velocity of movement using Doppler ultrasonography and coding them as colors and shades, respectively.
echo planar imaging  a technique for obtaining a magnetic resonance image in less than 50 msec.
electrostatic imaging  a method of visualizing deep structures of the body, in which an electron beam is passed through the patient and the emerging beam strikes an electrostatically charged plate, dissipating the charge according to the strength of the beam. A film is then made from the plate.
gated cardiac blood pool imaging  equilibrium radionuclide angiocardiography.
gated magnetic resonance imaging  a method for magnetic resonance imaging in which signal acquisition is gated to minimize motion or other artifacts.
hot spot imaging , infarct avid imaging see under scintigraphy.
magnetic resonance imaging  (MRI) a method of visualizing soft tissues of the body by applying an external magnetic field that makes it possible to distinguish between hydrogen atoms in different environments.
myocardial perfusion imaging  see under scintigraphy.
pyrophosphate imaging  infarct avid scintigraphy.
technetium Tc 99m pyrophosphate imaging 
2. any type of imaging using Tc 99m pyrophosphate as an imaging agent.


Visual representation of an object, such as a body part or celestial body, for the purpose of medical diagnosis or data collection, using any of a variety of techniques, such as ultrasonography or spectroscopy.


Etymology: L, imago
the formation of a mental picture or representation of someone or something using the imagination. See also fantasy.


Fringe medicine
See Native™ tissue harmonic imaging.
The production of non-invasive images of body regions using ionising radiation (e.g., CT or mammography) or electromagnetic radiation (e.g., MRI or ultrasonography), with or without radiocontrast. The information obtained is then analysed by a computer to produce a 2-D display.
Types of information provided
• Anatomic—CT, MRI, mammography, ultrasonography;
• Metabolic—PET, SPECT (single photon emission CT Electrical activity), SQUID.
The recording, transmitting and storing of images of pathologic lesions.


The term is used in 2 different areas of diagnostic medicine Radiology The production of non-invasive images of body regions using ionizing radiation–eg, CT or mammography, or electromagnetic radiation–eg, MRI or ultrasonography, with/without radiocontrast; the information obtained is then analyzed by a computer to produce a 2-D display Types of information provided Anatomic–CT, MRI, mammography, ultrasonography, metabolic–PET, SPECT-single photon emission CT or data on electrical activity–SQUID. See Brain imaging, Cardiac blood pool imaging, Contrast imaging, Diffusion-weighted imaging, Digital imaging, Document imaging, Doppler sonographic imaging, Echo planar imaging, Fast CT imaging, Fluorescence imaging, fMRI imaging, 4-D imaging, Freeze-fracture imaging, 1H imaging, Harmonic ultrasound imaging, Magnetic resonance imaging, Molecular imaging, Multiband imaging, Multiple plane imaging, Myocardial perfusion imaging, Native tissue harmonic imaging, Neuroimaging imaging, 32P imaging, Perfusion-weighted imaging, Real-time imaging, Sequential plane imaging, Somatostatin-receptor imaging, Spin-echo imaging, SQUID imaging, Structural imaging, Transient response imaging, Volume imaging.


Production of a clinical image using x-rays, ultrasound, computed tomography, magnetic resonance, radionuclide scanning, or thermography; especially, cross-sectional imaging (e.g., ultrasonography, computed tomography, magnetic resonance imaging).
See: image


The production of a picture, image, or shadow that represents the object being investigated. In diagnostic medicine the classic technique for imaging is radiographic or x-ray examination. Techniques using computer-generated images produced by x-ray, ultrasound, or magnetic resonance are also available.

black blood magnetic resonance imaging

Abbreviation: BB-MR
Imaging of arterial walls with magnetic resonance for evidence of atherosclerosis. Blood flow normally gives off a bright signal during magnetic resonance imaging but can be made to appear dark to distinguish it from the walls of the surrounding blood vessels. This enhancement in magnetic resonance imaging can be used noninvasively to show where arteries are obstructed and to determine the components of the plaque in those arteries.

cerebral blood pool imaging

Radionuclide brain imaging performed after a tracer molecule is injected angiographically into a blood vessel that supplies the brain and the tracer allowed to equilibrate (achieve a steady state) in the brain's arteries and veins.

diffusion tensor imaging

Abbreviation: DTI
An imaging technique in magnetic resonance imaging to identify the unique directional movement of molecules, esp. water molecules, along muscle and neural tracts. One of its uses is to identify the linkages and structures of white matter tracts in the brain.

diffusion weighted imaging

In magnetic resonance imaging, the use of changes in the movement of water through tissues as a contrast medium. Diffusion weighted imaging has been used in the diagnosis of strokes and other neurological diseases as well as abdominal and musculoskeletal injuries and diseases.

digital imaging

The capture and production of an image of an object, either on film or on a computerized display, where it can be reformatted and analyzed. Commonly used imaging modalities include x-rays, ultrasound, and magnetic resonance.

digital subtraction imaging

In radiology, the use of electronic means to subtract portions of the radiographic image in order to better visualize the object.

duplex imaging

A form of ultrasonography that incorporates both gray-scale imaging for the architecture of the tissue and a color Doppler signal for flow or movement within the tissue.

echo planar imaging

Abbreviation: EPI
A fast magnetic resonance imaging technique in which an image is acquired after a single radiofrequency excitation.

electrical source imaging

Abbreviation: ESI
A means of mapping the electrical activity of organs such as the brain or heart to diagnose or treat diseases such as seizures or dysrhythmias. ESI relies on the collection via external sensors of the electrical activity generated by multiple tissue sites within an organ, and the mathematical manipulation of that data to localize areas where patterns of electrical conduction are blocked or excessively active.

functional magnetic resonance imaging

Abbreviation: fMRI
The identification of metabolic activities during MRI studies of the brain. During an fMRI, magnetic resonance images of the brain are made while the subject performs specific tasks, e.g. using certain fingers or saying particular words. The study helps identify changes in blood flow during these activities, as well as changes in brain chemistry or the movement of water molecules in neural tissues. It is used to study brain injuries caused by cancer, multiple sclerosis, strokes, and trauma.

fusion imaging

Any combination of radiological technologies for generating images of body structures. Fusion imaging includes positron emission tomography-computed tomographic (PET-CT) scanning, CT–magnetic resonance fusion imaging, and single photon emissions computed tomographic (SPECT) fusion imaging.

gated blood pool imaging

Radioisotopic imaging of the heart, esp. of the muscular contraction of its walls and of its ejection fraction. Red blood cells are withdrawn and labeled with an isotope of technetium. A sequence of images is taken immediately after the radiolabeled blood is reinjected into a peripheral vein and allowed to circulate. The images are timed to begin with each ventricular depolarization (with each R wave of the electrocardiogram). Normally the ejection of blood from the heart occurs at the same time and with the same strength from all muscle segments. Areas of the heart affected by infarction may not move normally (they may be akinetic or hypokinetic) or they may move paradoxically (they may be dyskinetic, as when a ventricular aneurysm is present).
Synonym: gated blood pool study
Enlarge picture
MAGNETIC RESONANCE IMAGING: MRI of the cervical spine, sagittal view.
Enlarge picture

magnetic resonance imaging

Abbreviation: MRI
Imaging that uses the characteristic behavior of protons when placed in powerful magnetic fields to make images of tissues and organs. Certain atomic nuclei with an odd number of neutrons, protons, or both are subjected to a radiofrequency pulse, causing them to absorb and release energy. The resulting current passes through a radiofrequency receiver and is then transformed into an image. This technique is valuable in providing soft-tissue images of the central nervous and musculoskeletal systems. Imaging techniques allow visualization of the vascular system without the use of contrast agents. Agents such as gadolinium are available for contrast enhancement but must be used with caution in patients with renal insufficiency.


Magnetic resonance imaging is contraindicated in patients with cardiac pacemakers or ferromagnetic aneurysmal clips in place. Metal may become damaged during testing; therefore, health care providers must establish whether the patient has magnetizable metal anywhere on or in the body. Patients should not wear metal objects, e.g., jewelry, hair ornaments, or watches. Patients who have had surgical procedures after which magnetizable metal clips, pins, or other hardware remain in the body should not have this imaging. Some patients with tattoos or permanent cosmetics should also avoid MRI because of the risk of burns.

Patient care

During imaging, the patient lies on a flat surface that is moved inside a tube encompassed by a magnet (the bore of the gantry). The patient must lie as still as possible. No discomfort occurs as a result of the MRI. Sounds heard during the imaging come from the pulsing of the magnetic field as it scans the body. Confinement during the 30 to 90 min required for scanning may frighten the patient, but the patient can talk to staff by microphone. Relaxation techniques may help claustrophobic patients endure MRI. Comfort measures and analgesics (as necessary and prescribed) should be provided before beginning the scan to offset the discomfort related to prolonged positioning in the scanner. Claustrophobic patients may require a mild sedative, or be better managed in an open MRI scanner which is less confining, however open MRI devices, which use weaker magnetic fields than closed systems may take longer to obtain images and may reveal less detail. Right angle eyeglasses, which divert the patient's gaze outside the bore of the MRI gantry, provide a helpful diversion for some patients. Most patients, however, are able to tolerate the close confinement of the gantry. A nurse or MRI technologist should maintain verbal contact with the patient throughout the procedure. An IV line with no metal components should be in place if the patient’s condition is unstable. See: illustration; brain for illus.; positron emission tomography


myocardial perfusion imaging

Abbreviation: MPI
The use of radioactive isotopes, such as 201Tl or 99mTc sestamibi, to gauge the blood supply and viability of the regions or walls of the heart. MPI is frequently used to assess patients with coronary artery disease, often in conjunction with exercise tolerance tests. A patient with a coronary artery that is almost totally blocked may take up only a small quantity of radioisotope during exercise but much more of the tracer after several hours of rest. By contrast, heart muscle that is fed by a completely blocked artery will take up no radioisotope either during or after exercise.

near-infrared fluorescence imaging

Abbreviation: NIRI
Imaging of tissues within the body after they are bound by fluorescent molecules and stimulated with light in the 700-900 nm wavelength range. NIRI is used to provide images of solid cancers, bone and joint inflammation, and blood flow to tissues.

nuclear magnetic resonance imaging

Abbreviation: NMRI
See: magnetic resonance imaging

perfusion weighted imaging

In radioisotopic imaging, the use of differences in blood flow through organs as a means of diagnosing diseases such as strokes or malignancies.

physiological imaging

Imaging of the functions of an organ, i.e., of its blood flow, electrical activity, metabolism, oxygen uptake, or working receptors.

polarized helium imaging

A means of assessing asthma in which a magnetic resonance image is made of the lungs after a patient inhales polarized helium gas. Asthmatics have ventilation defects in the lungs that are not present in nonasthmatics.

radionuclide reflux imaging

Imaging to determine whether an infant has gastroesophageal reflux. Radioactively labeled milk is given to the child orally, and the progress of the milk through the upper gastrointestinal tract (and in reflux, into the lungs) is monitored. The scan is typically used if an infant has had more than one episode of aspiration pneumonia.

retinal vascular imaging

Measurement of the caliber of the blood vessels in the retina as risk markers for coronary and cerebrovascular disease. Narrowing of retinal arterioles has been correlated with an increased risk of diabetes mellitus and coronary artery disease. Dilation of retinal venules has been associated with an increased risk of stroke.

volumetric brain imaging

Measurement of the size of specific structures within the brain with magnetic resonance imaging or other devices. It is used to diagnose and identify brain diseases noninvasively. Atrophy of certain anterior brain structures is found in patients with frontotemporal dementia. In schizophrenia, the hippocampus and amygdala are reduced. Other findings have been demonstrated in depression, fragile X syndrome, Rett's disease, Tourette's syndrome, and other neurological disorders.
Synonym: volumetric neuroimaging


Production of a clinical image using x-rays, ultrasound, computed tomography, magnetic resonance imaging, radionuclide scanning, and thermography.
See: image


n the creation of digital, print, or film representations of anatomic structures for the purpose of diagnosis.


the production of diagnostic images, e.g., radiography, ultrasonography, or scintigraphy.

electrostatic imaging
a method of visualizing deep structures of the body, in which an electron beam is passed through the patient and the emerging beam strikes an electrostatically charged plate, dissipating the charge according to the strength of the beam. A film is then made from the plate.
nuclear imaging
organ imaging
outlining the size and location of organs by the injection of nuclides into the animal and observing their location by the use of a rectilinear scanner or a scintillation camera. See also scintigraphy.
References in periodicals archive ?
We are very excited to launch our newest product, Schultz CW Headphones for the true audiophiles.
Over the years, Hoffman has found that some artists, while happy their old albums are being given the audiophile treatment, don't really care to dwell on the reissue process.
Jason Liao, CTO & VP of Product Development at OPPO Digital, said: "The BDP-95 is OPPO Digital's flagship Universal Blu-ray Player designed from the ground up for Audiophile grade listening, using two ESS Sabre32 Reference DACs with Toroidal Power Supply to deliver astounding sound stage and unmatched fidelity in both 7.
Always entrenched in the music community, Altec Lansing continues to be a first choice for musicians and audiophiles alike.
There are passages throughout the piece, from the most quiet to the fortissimos where it is a perfect example of audiophile sound.
Featuring one audiophile display room and one fully functioning home theater display, Harman's Mobile Showroom has been touring the country for the last five months showcasing its high performance technologies to audiophiles, enthusiasts and dealers.
AEROSMITH - Four Classic Aerosmith 12" LPs, Individually Numbered on 180-gram audiophile vinyl
Recorded by Decca in 1967, it is one of the first things I considered an audiophile recording back in the old days when I was just getting started in the stereo field.
The Home Theater Review (HTR) Show will be open to the general public and will incorporate the best in high-resolution music, UltraHD video, audiophile components, home theater systems, installed premium car audio, high-end headphones and much more.
Audiophile Community Compares the SA6s with the World's Best In-Ear Earphones
ES30: The E30 is the next generation of a well-balanced three-driver system and is an ideal choice for the performing musician, audiophile and home/field sound engineers.
Yet even if one can typecast what type of person an audiophile is, there is no guarantee that someone struck by the audiophile bug is going to be blessed with an income of a CEO, successful physician, high-profile attorney, or royalty.