MDI

(redirected from SDI)
Also found in: Dictionary, Thesaurus, Acronyms, Encyclopedia, Wikipedia.

MDI

Abbreviation for metered-dose inhaler.

MDI

abbreviation for metered dose inhaler.

Major Depression Inventory

A self-report mood questionnaire developed by the World Health Organization that provides an estimate of symptom severity and generates a DSM-IV or ICD-10 diagnosis.

MDI

Abbreviation for metered-dose inhaler.

inhaler

(ĭn-hāl′ĕr)
1. A device for administering medicines by inhalation.
2. One who inhales.
Enlarge picture
METERED-DOSE INHALER

metered-dose inhaler

Abbreviation: MDI
A device used for self-administration of aerosolized drugs.

Patient care

When used correctly, a metered-dose inhaler can deliver accurate doses of medication to the respiratory tract. The MDI is a drug canister in an L-shaped mouthpiece, which can be used alone or with a “spacer” (a holding chamber designed to aerosolize medication so it can reach the lower respiratory tract). The health care professional teaching the patient proper MDI technique should gather the drug canister and mouthpiece, the package insert, and the spacer (if one is to be used). The MDI should be sprayed once or twice prior to initiating use, and the spacer inspected for foreign objects. The patient should wash his/her hands thoroughly, and may either sit or stand. If a peak flow meter is being used, the patient should take a reading prior to using the MDI. The patient should then clear the throat and nasal passages. The patient should hold the inhaler upright and shake it as directed, then remove the cap and hold the inhaler with the canister on top and the mouthpiece facing the patient's open mouth at the bottom. Tilting the head back slightly, the patient should breathe out slowly and completely. (When using an MDI with a spacer, the inhaler cap is removed and the mouthpiece is firmly inserted into the spacer, then the spacer and inhaler are held together upright and vigorously shaken 5 or 6 times. The space cap is then removed, the head tilted back, and the breath let out slowly and completely.) The inhaler mouthpiece may be positioned in one of two ways: 1 to 2 inches (2.5 to 5 cm) in front of the open mouth, mouth open; or with the mouthpiece in the mouth and lips sealed around it. However, this latter technique is less efficient in delivering medication and should never be used for steroids. While breathing in slowly, evenly, and deeply though the mouth, the patient should press once on the canister and continue inhaling for 3 to 5 sec. The breath should then be held for 10 sec (or as long as possible), allowing the medication to settle in the lungs. The inhaler should be removed from the mouth prior to exhaling. If a spacer is used, the patient should place the spacer mouthpiece in the mouth and seal the lips around it, then press on the canister to spray a puff of medication into the spacer and begin inhaling slowly through the mouth for 3 to 5 sec. The breath should then be held for 10 sec (or as long as possible). The spacer should be removed from the mouth prior to exhaling. If more than one puff is prescribed, the patient should wait 1 to 2 min between puffs to help the second puff to better penetrate the lungs. The patient should be taught to remember “B before C” when using an inhaled bronchodilator and corticosteroid; first inhaling the bronchodilator, waiting about 5 min, and then inhaling the corticosteroid. This helps to open the air passages for maximum absorption of the steroid. After inhaling a corticosteroid, the patient should rinse the mouth with water and expectorate it.

The spacer and the L-shaped mouthpiece and cap should be rinsed with warm, running water at least once each day, and washed with warm soapy water, then rinsed at least once each week. The equipment should always be allowed to air-dry. The patient can calculate how long a drug canister will last by reading the total number of doses on the label, counting the number of puffs used each day, and dividing the total doses by the number of daily puffs. (Thus if a canister contains 200 doses and the patient takes 8-10 each day, a new canister will be required in a month). The health care educator should provide the patient with written instructions and illustrations for proper MDI use. The patient also should be taught about (and provided with) information on the desired effects of each medication and the possible adverse reactions. The teaching session, the patient's demonstration of the method, and any questions raised should be documented in the patient's record.

See: illustration
Enlarge picture
METERED-DOSE INHALER

metered-dose inhaler

Abbreviation: MDI
A device used for self-administration of aerosolized drugs.

Patient care

When used correctly, a metered-dose inhaler can deliver accurate doses of medication to the respiratory tract. The MDI is a drug canister in an L-shaped mouthpiece, which can be used alone or with a “spacer” (a holding chamber designed to aerosolize medication so it can reach the lower respiratory tract). The health care professional teaching the patient proper MDI technique should gather the drug canister and mouthpiece, the package insert, and the spacer (if one is to be used). The MDI should be sprayed once or twice prior to initiating use, and the spacer inspected for foreign objects. The patient should wash his/her hands thoroughly, and may either sit or stand. If a peak flow meter is being used, the patient should take a reading prior to using the MDI. The patient should then clear the throat and nasal passages. The patient should hold the inhaler upright and shake it as directed, then remove the cap and hold the inhaler with the canister on top and the mouthpiece facing the patient's open mouth at the bottom. Tilting the head back slightly, the patient should breathe out slowly and completely. (When using an MDI with a spacer, the inhaler cap is removed and the mouthpiece is firmly inserted into the spacer, then the spacer and inhaler are held together upright and vigorously shaken 5 or 6 times. The space cap is then removed, the head tilted back, and the breath let out slowly and completely.) The inhaler mouthpiece may be positioned in one of two ways: 1 to 2 inches (2.5 to 5 cm) in front of the open mouth, mouth open; or with the mouthpiece in the mouth and lips sealed around it. However, this latter technique is less efficient in delivering medication and should never be used for steroids. While breathing in slowly, evenly, and deeply though the mouth, the patient should press once on the canister and continue inhaling for 3 to 5 sec. The breath should then be held for 10 sec (or as long as possible), allowing the medication to settle in the lungs. The inhaler should be removed from the mouth prior to exhaling. If a spacer is used, the patient should place the spacer mouthpiece in the mouth and seal the lips around it, then press on the canister to spray a puff of medication into the spacer and begin inhaling slowly through the mouth for 3 to 5 sec. The breath should then be held for 10 sec (or as long as possible). The spacer should be removed from the mouth prior to exhaling. If more than one puff is prescribed, the patient should wait 1 to 2 min between puffs to help the second puff to better penetrate the lungs. The patient should be taught to remember “B before C” when using an inhaled bronchodilator and corticosteroid; first inhaling the bronchodilator, waiting about 5 min, and then inhaling the corticosteroid. This helps to open the air passages for maximum absorption of the steroid. After inhaling a corticosteroid, the patient should rinse the mouth with water and expectorate it.

The spacer and the L-shaped mouthpiece and cap should be rinsed with warm, running water at least once each day, and washed with warm soapy water, then rinsed at least once each week. The equipment should always be allowed to air-dry. The patient can calculate how long a drug canister will last by reading the total number of doses on the label, counting the number of puffs used each day, and dividing the total doses by the number of daily puffs. (Thus if a canister contains 200 doses and the patient takes 8-10 each day, a new canister will be required in a month). The health care educator should provide the patient with written instructions and illustrations for proper MDI use. The patient also should be taught about (and provided with) information on the desired effects of each medication and the possible adverse reactions. The teaching session, the patient's demonstration of the method, and any questions raised should be documented in the patient's record.

See: illustration
See also: inhaler
References in periodicals archive ?
The dynamics of the SDI collaboration process in our study also have been identified in other studies on collaboration outside the SDI domain (Bailey and Koney 2000, Gadja 2004, Frey et al.
This means Mini Converter SDI to HDMI 4K supports both older Quad Link and new Dual Link 4K SDI connections, so is perfect for all 4K monitoring.
This award recognizes SDI as first in customer service among all North American commercial Maytag distributors.
SDI is the world's largest manufacturer of the devices used by the auto industry to activate air bags in a crash.
The wisdom of building SDI will be a certain issue in the 1988 presidential campaign: George Bush supports the plan while Michael Dukakis said this week he would replace SDI with a "conventional defense initiative.
But they are quick to add that even if SDI "is only 20 percent effective,' as one worker tells Broad, "the 20 percent that gets protected is an enormous retaliatory capability.
SDI Integrated Healthcare Network Profiling Solution SDI Hospital Market Profiling Solution SDI Medical Group Practice Profiling Solution SDI Diagnostic Imaging Center/Chain Profiling Solution SDI Freestanding Outpatient Surgery Center/Chain Profiling Solution SDI Home Health Agency/Chain Profiling Solution SDI Healthcare Market Index
Treinen said SDI probably will be hiring more than half of the 600 workers over the next year because many now employed at Newhall may not want to commute from their homes in the Antelope and Santa Clarita valleys.
Zimmerman adds that with a program with nearly three times the total budget of the National Science Foundation, SDI officials ought to be able to come up with more demonstrable improvement than this.
Because DeckLink SDI features broadcast quality SDI, and can instantly switch between SD-SDI and HD-SDI formats, it's perfect for connecting to decks such as HDCAM, HD-D5, Digital Betacam and more.
This year, Samsung SDI showcased not only its electronic vehicle Battery Business but also its Automobile Material Business and SDIBS (SDI Battery systems), Battery Pack Development Business undertaken from Magna this May.
Other SAI data analysis tools that SDI will be using include Purchase Analysis, Order Management and Inventory Analysis programs.