SCE


Also found in: Dictionary, Thesaurus, Acronyms, Encyclopedia, Wikipedia.

SCE

abbreviation for saturated calomel electrode.

electrode

(i-lek'trod?) [ electro- + Gr. hodos, a way]
1. An electrical terminal or lead.
2. A conductive medium.
3. In electrotherapy, an instrument with a point or surface from which to discharge current to a patient's body.
4. An electrical terminal or lead that is adapted to sense current or voltage in response to specific analytes, for purposes of quantifying the particular analyte.

active electrode

An electrode that is smaller than a dispersive electrode and produces stimulation in a concentrated area.

calomel electrode

An electrode that develops a standard electric potential and is used to provide a reference voltage in the circuit for sensing electrodes. It is composed of an amalgam of mercury and mercury (I) chloride. It is used as a standard in determining the pH of fluids.

carbon dioxide electrode

A blood gas electrode used to measure the carbon dioxide tension (symbolized as Pco2) in blood. Its operation is based on the diffusion of carbon dioxide from the blood sample through a semipermeable membrane into a buffer solution with a subsequent change in the pH of the buffer. Synonym: Severinghaus electrode

Clark electrode

Oxygen electrode.

coated wire electrode

Abbreviation: CWE
A chemical sensor in some clinical laboratory analyzers that functions similarly to a pH electrode. See: hydrogen electrode; saturated calomel electrode

depolarizing electrode

An electrode with greater resistance than the part of the body in the circuit.

dispersive electrode

Indifferent electrode.

gas-sensing electrode

An electrode in which a gas-permeable membrane separates the test solution fluid from an aqueous electrode solution in contact with an ion-selective electrode. Gas permeation of the membrane changes the chemical equilibrium within the electrolyte, and the ion-sensitive electrode detects this change.

glass electrode

In chemistry, a chemical sensor that uses a glass membrane as the sensing surface, as opposed to one that uses an organic or solid-state membrane. The glass contains materials in its structure that are sensitive to a material that is to be measured. In the case of a pH glass electrode, lithium ions are commonly used

hydrogen electrode

An electrode that absorbs and measures hydrogen gas; used as the reference for pH measurement in research laboratories.

immobilized enzyme electrode

A chemical sensor that is highly selective due to a specific enzyme incorporated into its structure.

indifferent electrode

An electrode larger than an active electrode. It produces electrical stimulation over a large area. Synonym: dispersive electrode.

internal reference electrode

The metal electrode inside all chemical-sensing potentiometric electrodes. The two most commonly used internal reference electrodes are the calomel and the silver/silver chloride.

ion-selective electrode

A chemical transducer that yields a response to variations in the concentration of a given ion in solution.

liquid membrane electrode

An electrode in which the sensing membrane is made up of a hydrophobic ion-exchange neutral carrier (ionophore) dissolved in a viscous, water-insoluble solvent. The liquid membrane is physically supported by an inert porous matrix such as cellulose acetate.

multiple point electrode

Several sets of terminals providing for the use of several electrodes.
See: multiterminal

negative electrode

A cathode; the pole by which electric current leaves the generating source.

oxygen electrode

An electrode used to measure the partial pressure of oxygen (Po2) or the blood glucose concentration of a fluid sample. Synonym: Clark electrode; Po2 electrode; polarographic electrode

PO2 electrode

Oxygen electrode.

point electrode

An electrode with an insulating handle at one end and a small metallic terminal at the other for use in applying static sparks.

polarographic electrode

Oxygen electrode.

polymer membrane electrode

An electrode in which the sensing membrane is an organic polymer containing a hydrophobic ion-exchange neutral carrier (ionophore).

positive electrode

An anode; the pole opposite a cathode.

reference electrode

A chemical electrode whose cell potential remains fixed and against which an indicator electrode is compared. The most common reference electrode is the silver/silver chloride (Ag/AgCl) electrode.

saturated calomel electrode

Abbreviation: SCE
One of two practical reference electrodes, used with a mercurous chloride (calomel) paste in pH and other potentiometric instruments. The other is the silver/silver chloride electrode. The calomel electrode has been the standard secondary reference electrode used in the laboratory since the introduction of the pH electrode.

Severinghaus electrode

Carbon dioxide electrode.

solid-state membrane electrode

An electrode in which the sensing membrane is made of a single crystal or pressed pellet containing the salt of the ion to be sensed.

standard hydrogen electrode

Abbreviation: SHE
The standard reference electrode against which all others are measured. Its assigned electrode potential is 0.000 V.

subcutaneous electrode

An electrode placed beneath the skin.

surface electrode

An electrode placed on the surface of the skin or exposed organ.

therapeutic electrode

An electrode used for introduction of medicines through the skin by ionization.
See: iontophoresis

saturated calomel electrode

Abbreviation: SCE
One of two practical reference electrodes, used with a mercurous chloride (calomel) paste in pH and other potentiometric instruments. The other is the silver/silver chloride electrode. The calomel electrode has been the standard secondary reference electrode used in the laboratory since the introduction of the pH electrode.
See also: electrode
References in periodicals archive ?
The system of policies and procedures revised by SCE starting last year include intensified and ongoing training regarding the CPUC s ex parte rules and the adoption of internal procedures that exceed current CPUC requirements.
SCE officials said they will refund any incentive rewards that have been inappropriately received, and forgo any future rewards that have not been properly earned.
While inter-company loans and guarantees exist within the EME corporate complex there are no cross defaults, inter-company loans or guarantees between EME and either EIX or SCE.
SCE engineers are collecting and analyzing data to determine how best to enable the safe and effective deployment of inverters on the utility's distribution circuits.
The CPUC has approved the Savings By Design effort through 2002 and SCE customers are encouraged to participate in the program before expanding operations.
Previous solicitations have secured more than 100 renewable energy contracts for billions of kilowatt-hours for SCE customers.
Called "qualifying facilities," or "QFs," these generators are smaller renewable and natural gas-fired power plants that provide approximately one-third of the electricity needed by SCE customers.
Gary Barsley, manager of the California Solar Initiative program, and Marc Ulrich, SCE vice president, Renewable and Alternative Power, also will participate.
16 /PRNewswire/ -- Southern California Edison (SCE), supported by an alliance of environmental, recreational, consumer and labor partners, has filed an application with the California Public Utilities Commission (CPUC), seeking approval to value its hydro electric generating facilities through a mechanism that would allow SCE to retain, maintain and operate those facilities within the utility.
After SCE customers provide facts such as location, daily power usage, vehicle type (such as a plug-in hybrid electric vehicle or battery-electric vehicle), mileage, and time of day use (on- or off-peak), the plug-in car rate assistant will provide an estimated comparison of the average monthly electricity and gasoline bills.