Printer Friendly
Dictionary, Encyclopedia and Thesaurus - The Free Dictionary
1,761,396,365 visitors served.
forum mailing list For webmasters
?
New: Language forums
Dictionary/
thesaurus
Medical
dictionary
Legal
dictionary
Financial
dictionary
Acronyms
 
Idioms
Encyclopedia
Wikipedia
encyclopedia
?

absorbed dose
(redirected from Dose, absorbed)

   Also found in: Encyclopedia, Wikipedia 0.01 sec.
dose (dōs) the quantity to be administered at one time, as a specified amount of medication or a given quantity of radiation.
absorbed dose  that amount of energy from ionizing radiations absorbed per unit mass of matter, expressed in rads.
air dose  see under exposure.
booster dose  a dose of an active immunizing agent, usually smaller than the initial dose, given to maintain immunity.
divided dose  fractionated d.
effective dose  (ED) that quantity of a drug that will produce the effects for which it is given.
erythema dose  the amount of radiation which, when applied to the skin, causes temporary reddening.
fatal dose  lethal d.
fractionated dose  a fraction of the total quantity of a prescribed drug or radiation to be given at intervals.
infective dose  that amount of pathogenic organisms that will cause infection in susceptible subjects.
infinitesimal dose  see under principle.
lethal dose  that quantity of an agent that will or may be sufficient to cause death.
maximum dose  the largest dose consistent with safety.
maximum permissible dose  (MPD) the largest amount of ionizing radiation that one may safely receive in a specified period according to recommended limits in radiation protection guides.
median curative dose  (CD50) a dose that abolishes symptoms in 50 per cent of test subjects.
median effective dose  (ED50) a dose that produces the desired effect in 50 per cent of a population.
median immunizing dose  the dose of vaccine or antigen sufficient to provide immunity in 50 per cent of test subjects.
median infective dose  (ID50) the amount of pathogenic microorganisms that will cause infection in 50 per cent of the test subjects.
median lethal dose  (LD50) the quantity of an agent that will kill 50 per cent of the test subjects; in radiology, the amount of radiation that will kill, within a specified period, 50 per cent of individuals in a large group or population.
median toxic dose  (TD50) the dose that produces a toxic effect in 50 per cent of the population.
minimum dose  the smallest dose that will produce an appreciable effect.
minimum lethal dose  (MLD)
1. the smallest amount of toxin that will kill an experimental animal.
2. the smallest quantity of diphtheria toxin that will kill a guinea pig of 250 g weight in 4 to 5 days when injected subcutaneously.
skin dose  (SD)
1. the air dose of radiation at the skin surface, comprising primary radiation plus backscatter.
2. the absorbed dose in the skin.
threshold dose  the minimum dose of ionizing radiation, a chemical, or a drug that will produce a detectable degree of any given effect.
threshold erythema dose  the single skin dose that will produce in 80 per cent of those tested a faint but definite erythema within 30 days, and in the other 20 per cent, no visible reaction. Abbreviated T.E.D.
tolerance dose  the largest quantity of an agent that may be administered without harm.

ab·sorbed dose (b-zôrbd)
n.
The quantity of radiation energy, expressed in rads, that is administered or absorbed per unit mass of target.

absorbed dose,
the energy imparted by ionizing radiation per unit mass of irradiated material at the place of interest. The SI unit of absorbed dose is the gray, which is 1 J/kg and equals 100 rad.

dose,
n 1. the quantity of drug necessary to produce a desired effect.
n 2. the total radiation delivered to a specified area or volume or to the whole body. See also dose, radiation-absorbed.
dose, absorbed (D),
n the amount of energy imparted by ionizing particles to unit mass of irradiated material at a place of interest. The unit of absorbed dose is the rad (100 ergs/Gm).
dose, air,
n a radiographic dose delivered at a point in free air; expressed in roentgens. It consists only of the radiation of the primary beam and the radiation scattered from surrounding air; does not include backscatter from radiated matter (e.g., tissue).
dose, booster,
n the portion of an immunizing agent given at a later time to stimulate the effects of a previous dose of the same agent.
dose, cumulative
(kū´myltiv),
n the total accumulated dose resulting from a single or repeated exposure to radiation of the same region or of the whole body. If used in area monitoring, it represents the accumulated radiation exposure over a given period.
dose, depth,
n the absorbed dose of radiation imparted to matter at a particular depth below the surface, usually expressed as “percentage depth dose.” See also dose, percentage depth.
dose, distribution,
n a representation of the variation of dose with position in any region of an irradiated object. The dose distribution may be measured using detectors small enough to avoid disturbing the distribution, or it may be calculated and expressed in mathematical form.
dose, doubling,
n the amount of ionizing radiation, absorbed by the gonads of the average person in a population over a period of several generations, that will result in a doubling of the current rate of spontaneous mutations.
dose, effect curve,
n See curve, dose effect.
dose, equivalent (DE),
n the product of absorbed dose and modifying factors, namely the quality factor (QF), distribution factor (DF), and any other necessary factors. The unit of dose equivalent is the rem (rads times qualifying factors).
dose, erythema
(erthē´m),
n the dose of radiation necessary to produce a temporary redness of the skin. This dose varies with the quality of radiation.
dose, exit,
n the absorbed dose delivered by a beam of radiation at the surface through which the beam emerges from a phantom or patient.
dose, exposure,
n See exposure.
dose, fractionation,
n a dose given by a number of shorter exposures over a longer period than would be required if the dose was given by a continuous exposure in one session at the same dose rate.
dose, gonadal,
n the dose of radiation absorbed by the gonads.
dose, integral (integral absorbed dose, volume dose),
n the total energy absorbed by a part or object during exposure to radiation. The unit of integral dose is the gram rad (100 ergs/gm).
dose, lethal,
n 1. the amount of a drug that would prove fatal to the majority of persons.
n 2. the amount of radiation that will be or may be sufficient to cause the death of an organism.
dose, maintenance,
n the quantity of drug necessary to sustain a normal physiologic state or a desired blood or tissue level of drug.
dose, maximum permissible (MPD),
n the maximum relative biologic effect dose that the body of a person or specific parts thereof shall be permitted to receive in a stated period. In most instances, for the roentgen rays used in dental radiography, it is satisfactory to consider the RBE dose in rems numerically equal to the absorbed dose in rads and the absorbed dose in rads numerically equal to the exposure dose in roentgens. See also dose, weekly permissible.
dose, median effective (ED50),
n a dose that, under standard conditions, is effective in 50% of a randomly selected group of subjects.
dose, median lethal (LD50),
n the amount of ionizing radiation required to kill, within a specified period, 50% of the individuals in a large group or population of animals or organisms.
dose, minimum lethal (MLD),
n the minimal amount of a drug that will kill an experimental animal.
dose, percentage depth,
n the ratio (expressed as a percentage) of the absorbed dose at a given depth in an irradiated body, to the absorbed dose at a fixed reference point on the central ray, usually the surface-absorbed dose.
dose, priming,
n a quantity several times larger than the maintenance dose; used at the initiation of therapy to rapidly establish the desired blood and tissue levels of the drug.
dose, protraction
(prōtrak´shn),
n a method of radiation administration delivered continuously over a relatively long period at a relatively low dosage rate.
dose, radiation,
n the amount of energy absorbed per unit mass of tissue at a site of interest. Note: This definition limits the use of “dose” to conform with the 1962 recommendations of the International Commission on Radiological Units and Measurements (ICRUM). The following terms therefore become obsolete but will be found in this dictionary under the general heading of exposure: air dose, cumulative dose, exposure dose, and threshold dose.
dose, radiation-absorbed (rad),
n the unit of absorbed dose, with a value of 100 ergs per gram.
dose, rate,
n the time rate at which radiation dose is applied, expressed in either roentgens per unit time or rads per unit time.
dose, safely tolerated (STD),
n the dose that can be safely tolerated without producing serious acute toxicity.
dose, skin,
n See dose, surface-absorbed.
dose, subantimicrobial
n the quantity of medication to be taken at one time for purposes other than the elimination of disease-causing microorganisms.
dose, surface-absorbed,
n the absorbed dose delivered by a radiation beam at the point where the central ray passes through the superficial layer of the phantom or patient.
dose, therapeutic,
n a quantity several times larger than the maintenance dose; used in vitamin therapy in which a marked deficiency exists.
dose, threshold,
n the minimum dose that will produce a detectable degree of any given effect.
dose, tissue,
n the dose absorbed by a tissue or tissues in a region of interest.
dose, tolerance,
n See dose, maximum permissible.
dose, toxic,
n the amount of a drug that causes untoward symptoms in the majority of persons.
dose, transit,
n a measure of the primary radiation transmitted through the patient and measured at a point on the central ray at some point beyond the patient.
dose, U.S.P,
n See dose, median effective (ED50); dose, lethal.
dose, volume,
n See dose, integral.
dose, weekly permissible,
n a dose of ionizing radiation accumulated in 1 week and of such magnitude that, in view of present knowledge, exposure at this weekly rate for an indefinite period of time is not expected to cause appreciable bodily injury during a person's lifetime.

dose
the quantity to be administered at one time, as a specified amount of medication or a given quantity of radiation.

absorbed dose
that amount of energy from ionizing radiations absorbed per unit mass of matter, expressed in Grays.
air dose
the intensity of an x- or gamma-ray beam in air, expressed in coulombs per kilogram.
booster dose
an amount of immunogen (vaccine, toxoid or other antigen preparation), sometimes smaller than the original amount, injected at an appropriate interval after primary immunization to enhance and sustain the immune response to that immunogen.
curative dose (CD)
a dose that is sufficient to restore normal health.
divided dose
a fraction of the total quantity of a drug prescribed to be given at intervals, usually during a 24-hour period.
dose equivalent limits
the limits of ionizing radiation set for radiation workers and the general public by the International Commission on Radiological Protection. For radiology workers this limit for the whole body is 50 mSv.
fatal dose
lethal dose.
dose fractions
in radiation therapy, the small doses given to reach the total radiation dose during the treatment period.
infectious dose 50 (ID50)
that amount of pathogenic microorganisms that will produce infection in 50% of the test subjects.
infective dose (ID)
that amount of pathogenic microorganisms that will cause infection in susceptible subjects.
lethal dose (LD)
the amount of toxin or drug that will kill an animal.
dose level
the amount administered per unit of body weight.
loading dose
the initial large dose of a drug given to bring tissue and fluid levels to an effective concentration quickly. Called also priming dose.
maintenance dose
the smaller doses given to maintain effective levels in body fluids and tissues after the loading dose has achieved the concentration desired.
maximum permissible dose
see dose equivalent limits (above).
median curative dose (CD50)
a dose that abolishes signs in 50% of test animals.
median effective dose (MED)
the dose that produces the desired effect in 50% of the test animals.
median lethal dose (MD50)
the quantity of an agent that will kill 50% of the test subjects; in radiology, the amount of radiation that will kill, within a specified period, 50% of individuals in a large group or population.
minimum lethal dose (MLD)
the lowest dose which kills all of the test subjects.
dose rate
the amount administered per unit of time.
dose response
1. the incremental change in the subject per unit of additional dose. The response as a function of the dose.
2. the frequency of occurrence of a disease as the intake of the suspected risk factor increases. The relationship is expressed by the proximity of the illustrative curve to the expected relationship.
skin dose
1. the air dose of radiation at the skin surface, comprising the primary radiation plus backscatter.
2. the absorbed dose in the skin.
tolerance dose
the largest quantity of an agent that may be administered without harm.

absorbed dose
Radiation physics The energy imparted by ionizing radiation per unit mass of irradiated material–eg, tissue, defined as an SI unit, the gray–Gy, which corresponds to the 100 rads, the old unit for absorbed dose


How to thank TFD for its existence? Tell a friend about us, add a link to this page, add the site to iGoogle, or visit webmaster's page for free fun content.
?Page tools
Printer friendly
Cite / link
Email
Feedback
Add definition
? Mentioned in
 
Medical browser? ? Full browser
 
 
Medical Dictionary
?

Disclaimer | Privacy policy | Feedback | Copyright © 2009 Farlex, Inc.
All content on this website, including dictionary, thesaurus, literature, geography, and other reference data is for informational purposes only. This information should not be considered complete, up to date, and is not intended to be used in place of a visit, consultation, or advice of a legal, medical, or any other professional. Terms of Use.